Oscilloscope active probe design

Oscilloscope active probe design. There are also resistive probes with only 0. TETRIS 1000 1 GHz high-impedance active oscilloscope probe 10:1. The second article discussed single-ended, differential, and high-voltage differential active probes. Feb 15, 2016 · There are two basic types of passive probe, low impedance probes and high impedance probes. 1 – 1500 MHz – 1. The minimized probe load capacitance is important when making critical oscilloscope measurements. Figure 2: The 1:1 shielded voltage probe is based on coax cable. A miniaturized shielded-loop with the size of 0. The probe can affect both your measurement results and the circuit under test and is more than just a signal conduit between the circuit under test and the scope. To find the right probe for your Keysight used oscilloscope, first consider the different types of oscilloscope probes to decide which one is needed for the measurement you are intending to make. Its input impedance is 1 MΩ, 1 pF and the dynamic range is 0 to ±8 V. The probe coaxial transmission line is terminated behind the oscilloscope front panel connector at the 50 ohm input of the oscilloscope vertical channel pre-amp. The Keysight DP0012A is the 1 GHz model of the DP001xA Series differential active probes. Select from the probe categories listed below to see what Keysight has to offer. The Keysight 1-GHz N2795A active probe is $1,111. The probe provides 1. 9 pF, this active probe offers high input impedance up to 750 MHz. It is an easy access to oscilloscope probe menu display for probe status/diagnostic information and to control probe DC offset. ly/Scopes_Sub Part 1: What is an Compare. Includes examples and exercises to boost understanding of AFM subsystem design, fabrication and integration. Part 3 will deal with current measurement and current probes. So we set up our system and measure our edge with an active probe, and see a 1. TETRIS 1500 1. Keysight’s AutoProbe interface provides the following: • DC voltage to power active probe circuitry. 5 GHz of bandwidth and high resistance (1 MΩ) and low capacitance (1 pF) input for low probe loading. 5 GHz single-ended active probe is the industry’s first low-cost high- impedance active probe for environmental chamber testing of ICs and electronic devices at temperatures ranging from -40 to +85 °C. Just like a skilled artist needs a variety of brushes to create a masterpiece, a power electronics engineer needs the right tools to design and test circuits. 450 ohms for an x10 probe). Introduction. Differential probes were typically more expensive and harder to use, and had less bandwidth than single-ended probes. Connect your 10x passive probe’s tip to your oscilloscope’s COMP signal and use the adjustment near the probe cable’s base where it connects to the oscilloscope. Passive probes are widely considered "general purpose" probes and are well suited for low frequency signals as circuit loading is minimised. pls suggest the circuit of active probe using FET trace CRO. This requires adjusting the compensation each time the probe is moved to a different scope. This is possible due to the probe's T-shaped housing, which Dec 25, 2020 · 1. Since this one seems to offer the required capacitance am wondering if it could do the job. An active probe includes a fast preamplifier, usually fitted in the probe tip itself. Figure 2 shows the design of a 1:1 shielded probe. By far the most used oscilloscope probes are the passive 10:1 attenuation probe. In the oscilloscope, there’s a 1 MΩ resistor for forming 10:1 input attenuation ratio. Besides excellent specifications, they . Even the “low-bandwidth” probes were still around 1GHz of bandwidth. These days, most engineers and technicians use active probes to connect high-bandwidth signals to oscilloscopes. September 24, 2018 By David Herres 5 Comments. The 1:1/10:1 probe has a switch that inserts what’s usually a 9 MΩ resistor in series with the signal. These are 10:1 high impedance passive probes with a bandwidth of 500 MHz and an input capacitance of 10 pF. The measurement accuracy and operator safety depend strongly on the probes and accessories that are used. 5 pF probe will be about 175 ohm. You may have used a long, needle-like pin as the Sep 15, 2021 · The N2797A 1. Good news first: If you buy a used MSOX3104T oscilloscope directly from us here at Keysight, four Keysight N2843A passive probes are Mar 18, 2024 · Use the formula: Required Bandwidth = 0. A low-end commercial active probe might be 1 Mohm // 1 pF, or Aug 10, 2017 · The input termination setting of the oscilloscope scope should be 1MΩ. To compensate the probe, it is driven with a square wave4. 5 days ago · Feign, Eric, "High-frequency probes drive 50-ohm measurements," RF Design, October 1998. Despite expectations, some budget probes perform comparably to more expensive ones, emphasizing that bandwidth alone is not the sole determinant of This Instructable will show you how to build a 1GHz* Fet-based Active Probe, the Fetprobe, for about 10$*, provided you have access to an electronics lab. You may have attached relatively short wires to the input of your probe so you could reach into a tight probe point and solder them in place. Available for despatch. Â Hook the probe to one leg of the crystal and the ground probe to ground. Meanwhile, oscilloscope probes can also be classified in terms of the offered level of attenuation of Jan 27, 2015 · 2015-01-27 1 Min Read. Active, high-impedance probes can be connected to spectrum analyzers, providing a practical and highly precise measurement solution to overcome an otherwise cumbersome RF testing issue. Don't miss out on this essential tool for accurate measurements! Aug 13, 2017 · In this concluding part, we'll cover the design and construction of an n:1 voltage probe and a current probe. These components are powered, typically through the oscilloscope or an external power source, and are essential for the probe’s operation. In the 1:1 mode, there is no series resistor Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. Passive probes provide the ruggedness and wide dynamic range suitable for visualising signals over a broad range of applications. In order to get the capacitance down you have to have the amplifier at the probe tip end of the scope cable. Feb 1, 2019 · That’s why there are active probes. Its input impedance is very high, but its output impedance is 50 Ω, allowing it to be connected to a 50-Ω scope input. Sep 24, 2018 · Active probes are more costly. It offers a cost-effective solution compared to its passive counterpart. Its 1MΩ input resistance and extremely low input capacitance (1 pF) provide Whether you need the high bandwidth and low loading of an active probe, an easy way to connect to surface mount ICs, or a passive probe to measure high voltages, there’s a wide selection of high-quality probes and accessories for your Infiniium oscilloscope. 15 mm consists of three layers of metal layer Choosing the active oscilloscope probe is like opening a door to a world of lower cost and simplicity. (See this article on in-amps if you need to brush up. The new probe system uses interchangeable probe heads that Mar 15, 2017 · The majority of passive oscilloscope probes contain an attenuator to both isolate the circuit under test from the capacitance of the cable, and compensation capacitors in parallel with each of the 2. By providing both industry-leading products and application-specific reference design resources, we can help you solve your top design challenges and accelerate your time-to-market. It is appropriate when the frequency of the signal under investigation is less than 600 MHz. 5 GHz high-impedance active oscilloscope probe 10:1. In most cases, an active probe is required. To get the most out of your oscilloscope, you need the right probes and accessories for your particular applications. Beyond the passive attenuated probe, there are a variety of other probes out there. 2 M ohm input impedance, it is ideal as a general purpose, high bandwidth passive probe for the Keysight 300 MHz - 1 GHz 6000 series, 7000, 8000 and 9000 Series oscilloscopes. Quantity. • Automatic detection of probe attenuation. Sometimes the best probe is no probe at all, and a coaxial cable is perfect. TETRIS range. Depending on your measurement needs, this connection can be made with something as simple as a length of wire or with something as sophisticated as an active differential probe. The P2056 is a state-of-the-art 10:1 miniature probe for oscilloscopes with up to 500 MHz bandwidth. Passive Probes. Higher-end probes - Utilizes digital signal processing to eliminate probe loading effects. The unique design of the TETRIS 2500 active probe allows for contact to adjacent square pins with 2. 9 items. The probes are designed to handle input voltages of at least 350 Vrms. Compare. Active high voltage probes are characterized by their active electronic components, such as amplifiers and buffers, integrated into the probe itself. Probe Types . It uses just three op amps in a classic instrumentation amplifier configuration [] Mar 31, 2016 · The circuit in the probe is really just an instrumentation amplifier design with a modified input stage and a 50 ohm output impedance. Jan 17, 2013 · A 500 MHz 10x high-Z probe will have an input capacitance of about 8 pF, at 500 MHz this probe will have an input impedance of 40 ohm. A 1X probe does not attenuate the signal, while a 10X probe attenuates the signal by a factor of 10. The 1 kohm // 1. Figure 2: The PP018 high impedance probe has a bandwidth of 500 MHz and Learn how probes are designed!Learn about acquisition board layout and ADC infrastructure!Click to subscribe! http://bit. Product. Application Note. The unique design of the TETRIS active probe allows for contact to adjacent square pins in 2. Test probes range from very simple, robust devices to complex probes that are sophisticated, expensive, and fragile. Many anomalies may be Aug 16, 2017 · Editor’s Note: This article on current measurement and current probes is the third of a three-part series on probes and their proper use. Sep 16, 2013 · Above 100 MHz, consider an active probe. Apr 24, 2022 · Been on the cheap I went to the big auction web page and found a “RF Active Probe 0. • Automatic control of selectable probe attenuation on some probes. A 10X probe indicates that the signal applied to the oscilloscope is one-tenth (1/10th) of the actual input signal amplitude. 5 mm 10:1 BNC single pack. Oscilloscope probes are also essential for power electronics testing. Whether you need the high bandwidth and low loading of an active probe, an easy way to connect to surface mount ICs or a passive probe to measure high voltages, there are a wide selection of high-quality probes and accessories for your Keysight Technologies, Inc Jan 24, 2024 · This article conducts a real-world analysis of oscilloscope probes, comparing their performance and impact on signal measurements. £ 1515. A standard passive probe usually provides a dual attenuation ratio - user-selectable 10:1 and 1:1 range. Part 1, covered high-impedance passive probes. High voltage differential probes from Tektronix can be used for signals up to 6000 V. I even saw a used broken one on eBay for $139. 10x probes are good for larger signals, have wider bandwidth, and load the Jul 25, 2011 · There are two basic types of oscilloscope probes — the active probes and the passive probes. This type of high voltage probe is the best choice for making non-ground referenced, floating or isolated measurements in large part due to its common mode rejection capability. The back-to-back silicon diodes in the D 1 clamp the input signal to plus or minus one forward-voltage drop, which limits signal excursions you apply to the spectrum analyzer's front end, thus protecting the Aug 1, 2014 · A poor oscilloscope probe can in-troduce overshoot and ringing on measured waveforms for these fast rise time signals. It is based on an Elektor-magazine article (see the pdf's addendum, section literature in my thesis) beside some other designs. Its input impedance is 1 MΩ, 1 pF and the dynamic range is 0 to ± 8 V. Courses. It provides truer signal reproduction and fidelity for Discover the top 6 active oscilloscope probes that will take your high-frequency signal analysis to the next level. Passive probes are inexpensive, rugged and easy to use in a wide variety of applications. Traditional Active Probes Traditional oscilloscope probes are designed as “browsers. The resultant scope display will appear as one of the three waveforms in figure 6. 1-ns rise time. Typically, for single-ended probes, the browser is outitted with two sockets, one to Oscilloscope Probes 101. I connected the probe to one of its 50 Ω inputs, configured the scope to calculate the frequency spectrum of the input (FFT function), and dragged the probe over Jan 22, 2019 · Following NXP guidelines for selecting the right passive components between antenna and Rx pins of PN7462 NFC controller, they recommend using an Active probe with a low capacitance (<2-3pF) for taking voltage measurements at the pins during communication. The unique design of the TETRIS 1500 active probe allows for contact to adjacent square pins in 2. e. The TETRIS® probes are shipped with a comprehensive set of accessories and durable soft pouch for safe storage. These products are designed, manufactured, and serviced by Tektronix. 6 V, 10 V, and 20 V. Sep 24, 2023 · What is an oscilloscope probe? Differential scope probes drawingDifferential scope probe, 60v, 200mhz, x10 > 1 ghz diy differential probesProbes probe oscilloscope differential schematic active current introduction typical technical articles figure. 4000 MHz — 4 GHz Bandwidth; Custom FET chip powered; 0. While most probes are designed to measure voltage, there are probes designed to measure AC or DC current. ” These devices are optimized to be held in your hand and moved from point to point for troubleshooting or debugging. Learn: The benefits and drawbacks of different probe types. Inductance on the probe tip (LUS) and ground lead (LG) will limit bandwidth but the small size will help minimise noise pickup. High-Frequency Differential Active Probes < 10 GHz. Lastly, when it comes to RF and microwave measurements, oscilloscope probes help you accurately capture and analyze high-frequency signals. high-frequency. The Keysight Technologies, Inc. Unlike a passive probe that can greatly load high-speed signals, an active Sep 30, 2022 · A differential probe is an active device which uses a differential amplifier to measure the difference between two signals. In stock. The Arduino PC Oscilloscope Design. Pure coaxial design and laser-trimmed resistors ensure highest signal fidelity along the signal Dec 27, 2011 · An oscilloscope is just a piece of a system that indicates how accurately users analyze and display signals. 4 pF of input capacitance, which perform even better. Although the attenuator in this case will reduce the effect of the probe buffer amplifier input capacitance, the attenuator is used primarily to increase the limited dynamic range of the buffer May 22, 2012 · When you buy a low- to mid-range oscilloscope, it usually comes standard with a high-impedance passive probe per oscilloscope channel. These probes provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs Aug 13, 2004 · passive probe design. This application note provides information on how to use oscilloscope probes in RF measurements using spectrum analyzers. 5 pF or so. 34/rise_time. Two most common attenuation factors are 1x and 10x. Aug 1, 2001 · At its simplest, a scope probe provides a physical and an electrical connection between a device or circuit under test and an oscilloscope's input amplifier. This is possible due to the probe's T-shaped housing allowing many If you use high-bandwidth active voltage probes, you may have tried some creative approaches to gain visibility into hard-to-reach nodes in your circuits. Stack Exchange Network Stack Exchange network consists of 183 Q&A communities including Stack Overflow , the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. introduces the RP1000 Series of oscilloscope probes, the latest addition to its line of passive and active differential probes. 3GHz Active Probes. The active probe design eliminates the need for expensive coaxial cables and termination resistors, reducing overall costs. For instance, when a 10:1 probe is connected to a 1-V signal, it will transmit 100 mV to the input of the oscilloscope. The TAP2500, TAP3500 Sep 24, 2018 · Basics of active and differential scope probes. Secondary objective would be to avoid the 10x signal loss. "Measurement Solutions for Disk Drive Design ," Tektronix Inc. This gives high-voltage differential probes an input voltage range from 1500 to 7000 volts. Discover which probe you should use and how to minimize a probe's effect on your measurements. Active probes are powered probes (they require a separate power source), which can amplify your signal or even pre-process it before it get to your scope. You then have a series resistor at the tip to give your scale factor (i. InfiniiMax probe system allows either differential or single-ended probing and largely eliminates past objections to differential probes. • Hi-Z+ Probes • Passive Probes • High-Frequency Differential Active Probes < 10 GHz Next, we will look at some measurements from the Michigan Might Mite transmitter. Imparts a hands-on curriculum for precision mechatronics and instrumentation with AFM and digital twin simulators. An active probe uses a buffer amplifier in the probe tip to reduce probe loading and to drive the 50 ohm probe coaxial transmission line. The author tests a variety of probes, including both high-quality and budget options, revealing surprising results. Daniel Kramnik built an active differential probe and looks like he is seeing about 400MHz usable bandwidth. The design of active probe fabricated by a four-layer PCB technique includes four parts such as a shielded-loop for detecting, transmission structure, power circuit and LNA circuit (shown in Figure 1). N5426A 12 GHz InfiniiMax ZIF-tip–kit of 10. Oct 18, 2021 · 2 THE DESIGN OF PROPOSED ACTIVE PROBE. Specific types include test prods, oscilloscope probes and current probes. More rigorous design constraints, more standardized processes 4. £ 879 Nov 21, 2016 · Active probes are characterized by higher bandwidth and in highly sensitive situations an additional advantage is reduced circuit loading. To connect the device under test (DUT) into the oscilloscopes, users will have to use probes, which are critical in terms of signal integrity. The probe can set scope attenuation and automatically switch to 50 Ω input impedance. Neither of the inputs are referenced to ground, so the diff probe will only compare them to each other, then output a signal that your oscilloscope can use. This differential probe extends the functionality of standard single-ended input oscilloscopes Probe Types. The engineer must determine if these aberrations are part of the design or if they are caused by the measurement system. Thus, a users with a 1 GHz oscilloscope and using a probe that supports 500 MHz bandwidth, is Rigol Technologies, Inc. Price. Active probes - The active circuit in the tip of the probe helps reduce the probe load capacitance to one-tenth of the value compared to passive probes. A 10X probe is often used to reduce the loading effect of the probe on the circuit being measured and to provide higher measurement range. In the case of an active probe, a buffer amplifier fol-lows the compensated attenuator to drive the signal down the probe cable. Even used ones on eBay. A test probe is a physical device used to connect electronic test equipment to a device under test (DUT). The Infiniium probes and accessories data sheet provides you the overview of all But why are active oscilloscope probes so expensive? I mean, they're hundreds, if not thousands of dollars. This is possible due to the probe's T-shaped housing allowing Create innovative and differentiated instrumentation & electronic test equipment with our high-performance signal chain, power, and processors products. 1x probes are good for small signals, but have limited bandwidth. If the frequency is not excessive, the probe parameter most responsible for loading (and therefore altering the behavior) of a circuit is primarily the dc resistance, which in a passive probe is quite high Dec 1, 2019 · FIGURE 9 – Here the probe is moved across an old Raspberry Pi 1 computer module, while a Tektronix MSO 70404C oscilloscope displays the measured signal and its frequency spectrum. The Rohde & Schwarz portfolio includes high-quality active and passive oscilloscope probes, power rail probes, multi-channel power probes, high voltage probes, current probes and EMC near-field probes. It can be used with signal speeds of up to 100 MHz. ) probe must be adjusted to suit the input capacitance of the oscilloscope. These characteristics make this versatile probe ideal for many of your day-to-day measurements. Due to its small size (compared against antennas) the most common use of these tools is to aid in detection of the source of a particular signal (emission), or as a local field-generating source (immunity), helping you to find weak spots in your device under test. Keysight offers a broad range of voltage, current, and optical probing solutions for InfiniiVision and Infiniium Series oscilloscopes. A test probe is often supplied as a test lead Mar 13, 2024 · 1. 5 GHz Analyzer Oszilloskop” that is essential the same design around a BF998 from an These probes, from high-voltage differential probes to active and passive probes, offer a wide range of capabilities to accurately measure and analyze power signals. A typical oscilloscope probe presents 10-15 pF of capacitance. Many circuits cannot tolerate this, and, at the least, this capacitance can cause significant ringing. May 3, 2021 · An oscilloscope probe is a device that makes a physical and electrical connection between a test point or signal source and an oscilloscope . Smooth support for design sizes of over 5,000 devices or 10,000 pads 3. Oct 24, 2018 · Passive (Modular) Probes are the most common type of oscilloscope probe. Â For the first measurement we will look at the waveform inside the oscillator stage of the circuit. oscilloscope. Impedance matching from the probe tip to channel input port is critical. With an input resistance of 1 MΩ and capacitance of 0. The entire probe core is made of a high-quality CeramCore™ ceramic hybrid. Whether you need the high bandwidth and low loading of an active probe, an easy way to connect to surface mount ICs or a passive probe to measure high voltages, there are a wide selection of high-quality probes and accessories for your Keysight Technologies, Inc May 29, 2023 · Probes are available with various attenuation ratios, such as 1:1, 10:1, 100:1, and 1000:1. This pc oscilloscope has some excellent features like an auto-trigger, a frequency counter, a 50k sample/seconds, and a selectable voltage range – 5V, 6. With low circuit loading, and a form factor that allows probing in confined areas, the active voltage probe becomes the everyday probe for all different types of signals and connection points. To make this DIY oscilloscope, you Feb 6, 2024 · Presents the instrument design details of atomic force microscopy with focus on active cantilever probes. Low impedance probes are used with the scope input set to 50 ohm mode and a 50 ohm coax line to the scope. The TAP2500 is a Single-ended Active FET Probe provides excellent high-speed electrical and mechanical performance required for today's digital system designs. This type of probe is a very efficient tool, as its input capacitance can be small, down to 0. For enterprises, more professional users Nov 10, 2020 · TA043 100 MHz 700 V differential oscilloscope probe 10:1/100:1. 54 mm pitch simultaneously. Aside from being cheaper, passive probes are more preferred by oscilloscope users since they can also be used to take a vast variety of measurements. I guess the answer must be something to do with low volume and calibration process, but still so expensive. In this course, we will learn the essentials of oscilloscope probing. Hi-Z+ Probes. As part of the measurement chain, the probe affects both measurement results and circuit-under-test operation. the scope’s compact design (1U high by ½ rack wide) enables two DS8000-R P2056 passive oscilloscope probe: 500 MHz 2. , Literature number 47W-8257-2, April 1992. This probe should give good results but is a pricey option. The N2795A is a new generation of low-cost, single-ended active probe with the AutoProbe interface. In his article, Andrew describes his design of a high-voltage differential probe with features similar to commercial devices, but at a considerably lower cost. Active Probe Setup (via xellers) Back when I worked for an Oscilloscope company, we were pretty proud of our differential probes. Jan 5, 2023 · A differential probe measures the difference between the inputs. TETRIS 2500 2. Feb 10, 2021 · Simple plain coax connected to the square wave generator, and the oscilloscope set to its normal 1 Mohm setting. The home-made resistive probe, connected to the oscilloscope set to 50 ohm input ; Active FET probe. At high speeds, the parasitics introduced when an oscilloscope probe makes contact with Jul 22, 1999 · The scope probe is a crucial link in the measurement chain. The TA043 is an active differential probe suitable for high common-mode voltage measurement applications up to ±700 V (DC + peak AC). 2 MΩ (when terminated into 1 MOhm) The Keysight 10073D passive probe is our most rugged 500 MHz probe. Jun 9, 2021 · An active probe interface on these scopes allows the use of optional matching 750MHz or 1. TA223. The Keysight 2 GHz N2796A active probe is $2,253. Access Source Code. They offer a wide dynamic range and bandwidth as high as >500 MHz when connected to 1 M? input of the oscilloscope. Specifically designed for use and direct connection to oscilloscopes with the TekVPI™ probe interface, the TAP2500, TAP3500 and TAP4000 Active FET probes achieve high-speed signal acquisition and measurement fidelity by solving three traditional problems: Tektronix is ISO 14001:2015 and ISO 9001:2015 certified by DEKRA. Compared to active probes, passive probes are more rugged and less expensive. The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. They enable you to examine how your power circuits are functioning and identify any issues. Pico Technology presents a unique Inline Probing System – the TETRIS ® active probe. 4000 MHz — Linear dynamic range: Up to 60 V DC, 1Vp-p to bandwidth 4 Passive probes are the most common type of oscilloscope probe. Nov 29, 2018 · A very useful tool for troubleshooting EMC issues is the near field probe. If you want to know how to make a basic oscilloscope, then this design will be of immense help. This will be a bad method as will be visible in the ‘scope traces. 50 Ω, n:1 voltage probe Basic 1:1 passive probes are extremely useful so long as the signal reaching the oscilloscope isn't more than the input amplifiers can handle. High-voltage differential probes include attenuators and overload protection on each input. 1500 MHz — High Input Impedance; Interchangeable Spring Tips; Contacts adjacent Pins in 2. The probe integrates many of the characteristics needed for today's general-purpose, high-speed probing - especially in digital system design, component design/characterization, and educational research applications. Â The waveform will look like this: You can see that the oscillator is generating a TETRIS 2500 2. Jan 2, 2020 · The main objective of an active scope probe is to reduce the 11 pF to 15 pF shunt capacitance of a normal divide by 10 passive scope probe. High-Frequency Differential Active Input resistance: 2. 5 mm × 0. These characteristics make it the ideal probe for most of your daily measurements. • Probe DC offset on many probes. We then disconnect the active probe and connect Introduction. Jul 21, 2005 · You can also use this active probe in place of standard 1-to-1 or 10-to-1 oscilloscope probes, thus extending the design's applicability. Typical attenuation values are in the range of 50:1 to 2000:1. 54 mm Pitch Active Probe PMK. With a 10:1 attenuation ratio and high 2. 6pF Input Impendance; Wide Dynamic Range Active Probe PMK. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows Jul 12, 2017 · Teledyne LeCroy’s HDO4104A four channel, 1 GHz oscilloscope comes with four PP018-1 probes. From a practical standpoint, a major difference between active and The 1X and 10X factors on an oscilloscope probe refer to the attenuation of the probe. Keysight offers a broad range of voltage, current, and optical probing solutions for Apr 1, 2019 · Amplifiers in Action A high-voltage differential probe is a critical piece of test equipment for looking at high-voltage signals. Common probing mistakes engineers make. zx fq qx lc ai ex og rf hx sl